Article | Proceedings of the 56th Conference on Simulation and Modelling (SIMS 56), October, 7-9, 2015, Linköping University, Sweden | Heat Pump Efficiencies Simulated with Aspen HYSYS and Aspen Plus
Göm menyn

Title:
Heat Pump Efficiencies Simulated with Aspen HYSYS and Aspen Plus
Author:
Lars Erik Øi: Department of Process, Energy and Environmental Technology, Telemark University College, Norway Irene Yuste Tirados: Department of Process, Energy and Environmental Technology, Telemark University College, Norway
DOI:
10.3384/ecp15119141
Download:
Full text (pdf)
Year:
2015
Conference:
Proceedings of the 56th Conference on Simulation and Modelling (SIMS 56), October, 7-9, 2015, Linköping University, Sweden
Issue:
119
Article no.:
014
Pages:
141-147
No. of pages:
7
Publication type:
Abstract and Fulltext
Published:
2015-11-25
ISBN:
978-91-7685-900-1
Series:
Linköping Electronic Conference Proceedings
ISSN (print):
1650-3686
ISSN (online):
1650-3740
Publisher:
Linköping University Electronic Press, Linköpings universitet


Export in BibTex, RIS or text

Heat pump technology provides an efficient and sustainable solution for both heating and cooling. A traditional heat pump can be defined as a mechanical-compression cycle refrigeration system powered by electricity. Traditional refrigerants used in heat pumps are ammonia or chlorinated and fluorinated hydrocarbons. Because many of these chlorofluorohydrocarbons (CFC‚Äôs) are ozone-depleting components, evaluation of more environmentally friendly refrigerants like pure hydrocarbons is important. The efficiency of a heat pump is traditionally measured by the ratio of delivered heat at a high temperature divided by the electricity (or work) input. This is defined as the coefficient of performance (COP). There are several simulation tools available for the simulation of heat pumps. Traditional process simulation tools like Aspen HYSYS or Aspen Plus are useful because they have data for several components inside the program, and many thermodynamic models like equations of states available. It is of interest to calculate the efficiency of a heat pump system when varying temperature conditions, refrigerants, simulation programs and thermodynamic models. There are few references to such comparisons in the open literature. The circulation medium (refrigerant) alternates by the help of a compressor and an expansion valve between the temperatures 22 and 7, 24 and 5 or 24 and -15 ¬įC. The lowest temperature is the evaporation temperature and the highest is the condensing temperature. The pressures were specified as the saturation pressures at the given temperatures. The evaluated components are ammonia, R-11, R-12, R-22 and propane. The equations of state Peng-Robinson and Soave-Redlich-Kwong (SRK) and the activity model Non-Random-Two-Liquid (NRTL) were used in the process simulation programs Aspen HYSYS and Aspen Plus. COP values have been calculated to values between 3 and 9. The highest COP was calculated for the lowest temperature difference. The components giving the highest COP value between the temperatures 22 and 7 ¬įC were ammonia and R-12, and R-22 gave the highest COP between -15 to 22 ¬įC. Propane (which is not a CFC) gave slightly lower COP values than the other components. The differences between the thermodynamic models and the different programs were normally low. However, some differences between Aspen Plus and Aspen HYSYS for the same model were calculated. The calculated deviations between the same models using different programs are difficult to explain. Different model parameters in different programs may explain differences between the same models in different programs. Aspen Plus and Aspen HYSYS are evaluated to be powerful tools for heat pump calculations. The calculated differences between heat pump efficiencies with different components at different conditions are thought to be reasonable.

Keywords: heat pump; Aspen HYSYS; Aspen Plus; refrigerant; COP

Proceedings of the 56th Conference on Simulation and Modelling (SIMS 56), October, 7-9, 2015, Linköping University, Sweden

Author:
Lars Erik Øi, Irene Yuste Tirados
Title:
Heat Pump Efficiencies Simulated with Aspen HYSYS and Aspen Plus
DOI:
http://dx.doi.org/10.3384/ecp15119141
References:

AspenTech: Aspen Physical Property System 11.1, 2001.


P.A. Domanski and D.A. Didion: Simulation of heat pump operating with nonazeotropic mixture. ASHRAE Technical Data Bulletin, 91(3):54, 1985.


EU Parliament: Regulation (EC) No 1005/2009 on Substances that Deplete the Ozone Layer, 2009.


Hyprotech: HYSYS Simulation Basis, 2003.


A. Peneloux, E. Rauzy and R. Freze: A Consistent Correction for Redlich-Kwong-Soave Volumes: Fluid Phase Equilibria, 8:7-23, 1982.


D.Y. Peng and D.B. Robinson: A New Two-Constant Equation of State. Industrial and Engineering Chemistry Fundamentals, 15(1):59-64, 1976.


H. Renon and J.M. Prausnitz: Local compositions in Thermodynamic Excess Functions for Liquid Mixtures. A.I.Ch.E. Journal, 14(1):135-144, 1968.


J.M. Smith, H.C. Van Ness and M.M. Abbott. Introduction to Chemical Engineering Thermodynamics, 7th ed., McGraw Hill, 2005.


G. Soave: Equilibrium Constants from a Modified Redlich-Kwong Equation of State. Chemical Engineering Science, 27:1197-1203, 1972.


I.Y. Tirados: Heat pump efficiencies simulated with Aspen HYSYS and Aspen Plus. Master Thesis, Telemark University College, 2015.

Proceedings of the 56th Conference on Simulation and Modelling (SIMS 56), October, 7-9, 2015, Linköping University, Sweden

Author:
Lars Erik Øi, Irene Yuste Tirados
Title:
Heat Pump Efficiencies Simulated with Aspen HYSYS and Aspen Plus
DOI:
http://dx.doi.org/10.3384/ecp15119141
Note: the following are taken directly from CrossRef
Citations:
No citations available at the moment


Responsible for this page: Peter Berkesand
Last updated: 2017-02-21